

This results in fewer error messages in DiaSys when communicating with an EIM.ġ1.The default path to load profile data has been changed from “A:\” to “C:\ProgramData\DiaSys\Loadprofile_data”. under changes 2.71 -> 2.72) the code is no longer necessary.Īdvantage: The file is no longer blocked by the virus scanner.Ĩ.Data transfer by files – import: During import no more errors occur if the path to the data to be imported contains spaces.ĩ.Change of the message text if it is detected during the connection to the ECU that the crash recorder is blocked.īackground: Crash recorder data have to be transmitted to MTU.ġ0.Increased timeout for communication with EIM. Since DiaSys 2.72 the file is no longer executed but is directly unpacked when importing DiaSys (see point 3. However, the self-extracting executable code is no longer included. Here more detailed information about an alarm/error is displayed (if available).Ĥ.ECU-9, SXU: Bag learning maps (NTE-Events Lifetime xxx) are fed back to the central database as operating data analogous to load profile, error memory, etc.ĥ.Possible message texts when fetching data from the central database have been improvedĦ.ECU-9, SXU: New recording templates added to template database TemplateKD.mdbħ.Data transfer by files – export: The data will still be exported as one file with the extension *.EXE. Otherwise an error message will be displayed during the import: “The external table does not have the expected format.”ģ.ECU-9, SXU, EXU roles: “Chronological error log” has been extended by the columns “Detail information” and “Detail number”. –> If an XLSX file must be imported, it must first be converted into an XLS file using Excel. This is due to the increased problems with virus scanners, which classify Office files, which may contain macros, as unsafe.ĪTTENTION: The Excel import still only works with XLS files Instructions can be found under C:\Program files (x86)\DiaSys\Doku\IXXAT\usb-to-can V2 Firmwareupdate_howto.pdfĢ.The Excel format for Excel export has been changed from *.XLS to *.XLSX To prevent this, the current IXXAT firmware 1.07 have to be installed. Price only for ONE PC Installation and activationġ.IXXAT USB-to-CAN V2: Older firmware versions of the IXXAT interface USB-to-CAN V2 (professional and compact) may lose CAN messages.

Note:After payment,the download link will show on page,if you can not get it,pls contact on Whatsapp or DiaSys 2.73 Features: MTU DiaSys is designed to diagnosis for MTU engine controllers.You are able to use to do perform maintenance and service function,include reading and recording measurement values/process variables.
